Product Line

MF( Middle Flow ) series Nitrogen generator
MF Series Nitrogen generators

MF( Middle Flow ) series Nitrogen generator

Description

Features
Our MF series nitrogen generator uses a hollow fiber membrane module and reputable air filters, and can produce nitrogen gas of the highest purity (99.5 %).
Our nitrogen hollow fiber membranes are designed with openings that are 3.0 Å .

Compressed air is used to push/force oxygen and nitrogen molecules through to this membrane. Since oxygen molecules are much smaller than nitrogen molecules (2.9 Å vs. 3.1 Å ), they can easily escape through the membrane openings and be released into the air. Nitrogen molecules being much larger, are incapable of escaping through the openings, and are therefore directed into a tube where they make their way to a nitrogen storage tank module.

Easy to install, and requires no electrical connections. Optional analyzer helps monitor oxygen (O2) and nitrogen (N2) purity levels.

Features

Applications

Ideally supplies nitrogen gas for LC/MS/MS, QDa, MP/AES,ELSD, sample evaporators, and much more.
Fire-proofing of cased objects, paintings, and other museum collections.
Metal and composite metals heat-treatment and laser cutting.
Food packaging and processing.
Electronics manufacturing.
Pharmaceutical/laboratory research.
Plastic Injection Molding.
Oil, natural gas, and petrol industries.
Wine and other beverages production lines.

Why use gas generators instead of gas cylinders ?
Because nitrogen gas cylinders operate at very high pressures (up to 125 bar), numerous safety hazards exist and must be taken very seriously as sources of potential danger. They may explode and
cause extensive physical damage to property, equipment, and personnel. Additionally, their cumbersome manual handling and storage add to the concerns.
Using nitrogen generators eliminate :
• The manual handling, storage, and changing of high pressure nitrogen gas cylinders
• Potentially lethal leaks of nitrogen gas from piping systems

Specification
Product information
Model\N2 Purity N2 flow rate (Liters/min) @ inlet air 8 barg & 25oC
95% 96% 97% 98% 99%
MF-250 55 45 35 25 15
MF-500 130 110 80 65 40
MF-1000 260 220 160 130 80
MF-1500 390 330 240 195 120
Technical specifications
Model MF-250 MF-500 MF-1000 MF-1500
Min./Max. outlet pressure 4.14 barg/10 barg(60 psig / 145 psig)
Min./Max. Temperature 4˚C / 60˚C (40˚F / 140˚F )
Recommend inlet temperature 25˚C (77˚F)
Dimension(WxDxH) 46 cm ×28 cm ×112 cm
Weight 32 Kg 39 Kg 46 Kg 55 Kg
Option : Oxygen analyzer
Power voltage range 100~240VAC/50~60Hz(for O2 sensor only)
Test time 14 ±2 sec
Purity range
(N2)
@40.00%~99.99%

Loading...
Loading...